Accident Summary Nr: 981399 - Employee dies of asphyxia in silo

Accident Summary Nr: 981399 -- Report ID: 0551800 -- Event Date: 11/02/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10800084511/07/198952510New Paris Industries Inc

Abstract: At approximately 8:30 a.m. on November 2, 1989, Employee #1 and a coworker arrived at McKibben Farm to change the air bags in a silo. Both men climbed the silo and then Employee #1 told the coworker that he would go into the silo with a ladder. They opened the hatches on top of the silo. Employee #1 said that they did not need to put the blower on the silo and blow air into it. They waited about an hour before climbing into the silo. Employee #1 had descended approximately 12 feet when the ladder fell backward and he fell approximately 15 feet into the lower part of the silage. He looked up and said that the gas was bad. He started to climb back up the ladder, but then fell off, apparently losing consciousness because of a lack of oxygen. The coworker yelled down to the employee, but he did not respond and the coworker ran to get help. The fire-rescue team retrieved Employee #1 from the silo but was unable to revive him. Employee #1 died of asphyxia.

Keywords: OXYGEN DEFICIENCY, UNCONSCIOUSNESS, ASPHYXIATED, VENTILATION, CONFINED SPACE, WORK RULES, GAS, SCBA, FALL, SILO

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 108000845 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close