Accident Summary Nr: 977074 - One employee killed, one injured when boom collapses

Accident Summary Nr: 977074 -- Report ID: 0454713 -- Event Date: 08/10/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10552822808/12/198716220Scott Bridge Company Inc

Abstract: Employees #1 and #2 were members of a bridge construction crew that was using an American 100 ton capacity crane to move a 44,300 lb template into place. Employee #1 was standing on the barge on which the crane was mounted, and Employee #2 was on the barge arranging the rigging to hook up the template to the crane's two wire rope lifting cables. The boom collapsed and fell, striking Employee #1 on the back and pinning him against the barge dock. He was killed. Employee #2 was knocked into the river by a cable that whipped across the barge when the boom collapsed. He was wearing a life vest and was pulled from the water by coworkers. He sustained multiple bruises and contusions on his legs and was hospitalized.

Keywords: BARGE, WIRE ROPE, COLLAPSE, CRANE BOOM, CONSTRUCTION, RIVER, STRUCK BY, FALLING OBJECT, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105528228 Fatality Other Construction trades, n.e.c.
2 105528228 Hospitalized injury Bruise/Contus/Abras Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close