Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 976951 - Employee's finger amputated by punch press

Accident Summary Nr: 976951 -- Report ID: 0551800 -- Event Date: 03/03/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
11499700003/11/199434690Imperial Stamping Corporation

Abstract: At or about 3:15 p.m. on March 3, 1994, Employee #1 was operating a Toledo #7 80-ton full revolution mechanical power punch press. She was forming and punching a flat 12 gauge piece of steel that was 23 in. long and 2 1/2 in. wide into a bracket for a van part. The employee would insert the piece into the die area with her left hand, step on the foot control, then remove the part with her right hand. As she removed a part, the press reportedly cycled and caught her fingers in the die area. Three fingers on her right hand were amputated. The employee said that she did not step on the foot control and that the press came down on its own although she was wearing pull backs, which the employer admitted were not adjusted properly. According to the employee, the set-up man set them up for the part before it was formed and forgot that after the part is formed in this press, it is approximately 3/4 in. higher. He forgot to allow for this difference when he adjusted the pull backs for the employee. The next day the company advised all press operators that all parts will be inserted and removed by hand tools.

Keywords: POWER PRESS, WORK RULES, CAUGHT BY, POINT OF OPERATION, FOOT-POWERED PRESS, SET UP, PRESS OPERATOR, PUNCH PRESS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 114997000 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close