Accident Summary Nr: 96757.015 - Employee is asphyxiated inside manhole and is killed

Accident Summary Nr: 96757.015 -- Report ID: 0418800 -- Event Date: 01/16/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1243748.01501/16/2017237110Douglas N. Higgins Inc; Mckenna Contracting Llc; Dba D.N. Higgins

Abstract: At 8:30 a.m. on January 16, 2017, an employee was descending a ladder into a manhole to repair a leaking pipe. The employee was overcome by gasses inside the manhole and was asphyxiated by hydrogen sulfide and methane gas.

Keywords: Asphyxiated, Confined Space, Hydrogen Sulfide, Manhole, Methane
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction Alteration or rehabilitation $1,000,000 to $5,000,000 0 0 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1243748.015 34 M Fatality Pipelayer Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause:
2 1243748.015 24 M Fatality Pipelayer Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause:
3 1243748.015 49 M Fatality Pipelayer Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.