Accident Summary Nr: 959882 - ELECTRIC SHOCK & FALL - CONTACT WITH OVERHEAD LINE

Accident Summary Nr: 959882 -- Report ID: 0950621 -- Event Date: 01/02/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11205464801/16/199249320Pacific Gas And Electric

Abstract: A POWER LINE WORKER FOR AN ELECTRIC UTILITY CLIMBED A WOOD UTILITY POLE TO DISCONNECT A RESIDENTIAL ELECTRICAL SERVICE. HE WAS WORKING AT A HEIGHT OF ABOUT 27 FEET ABOVE THE GROUND. HE WAS WEARING LEATHER GLOVES, WHICH WERE DRY WHEN HE BEGAN TO CLIMB THE POLE. HOWEVER, THE MORNING WAS COLD AND DAMP. WHEN HE REACHED HIS WORKING POSITION AND FASTENED HIS BODY BELT AND SAFETY STRAP, HE REACHED OUT FROM THE POLE WITH A PAIR OF LINE CUTTERS IN ONE HAND AS HE HELD ON WITH HIS OTHER HAND. THE HAND THAT WAS HOLDING ONTO THE POLE WAS CONTACTING THE BARE NEUTRAL CONDUCTOR, WHICH WAS ANCHORED TO THE POLE. WHEN THE EMPLOYEE CUT INTO THE 120-VOLT SERVICE CONDUCTOR, HE RECEIVED AN ELECTRIC SHOCK AND COULD NOT LET GO. TO FREE HIMSELF, THE EMPLOYEE PULLED BACK, AND HIS GAFFS CUT OUT. HE FELL TO THE GROUND IN A PRONE POSITION. THE EMPLOYEE WAS HOSPITALIZED FOR A BROKEN HIP AND POSSIBLE ELECTRICAL BURNS.

Keywords: ELEC PROTECT EQUIP, OVERHEAD POWER LINE, ELECTRICAL, POWER LINE WORKER, E PTD, ELEC UTILITY WORK, ELECTRIC SHOCK, FALL, FALL PROTECTION, CUTOUT--GAFF

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112054648 Hospitalized injury Fracture Electrical power installers and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close