Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 958959 - Employee's wrist burned by chlorine flash

Accident Summary Nr: 958959 -- Report ID: 0950624 -- Event Date: 12/23/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11192011201/30/199249520Ca. State Dept. Of Correction Sierra Conservation

Abstract: At approximately 11:00 a.m. on December 23, 1991, at the Sierra Conservation Center, a medium security prison, Employee #1, an experienced water/sewage plant supervisor, preparing to change a 1 ton chlorine cylinder, disconnected a vacuum line from the nearly empty cylinder. The cylinder valve was in the OFF position and the vacuum had been allowed to purge the regulator for several minutes. Because an electric regulator heater had never been installed, according to an in-house investigation, entrained water vapor apparently froze in the drip trap, isolating recondensed chlorine. When the regulator was removed from the tank, the chlorine flashed to vapor and caused a chemical burn to Employee #1's right wrist. Employee #1 also suffered a delayed reaction to chlorine inhalation. He was hospitalized for 24 hours for observation and treatment. A regulator heater was installed immediately. Note that December 23 was an extremely cold day. No chlorine release had ever been experienced at this location during cylinder changes before this accident. An approved SCBA had been moved up to within 50 ft of the cylinder before the cylinder change.

Keywords: VAPOR, WORK RULES, INHALATION, GAS, CHLORINE, CHEMICAL BURN, WRIST

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111920112 Hospitalized injury Other Water and sewage treatment plant operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.