Accident Report Detail
Accident Summary Nr: 95669.015 - Employee is asphyxiated when respirator is hooked to nitroge
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1233587.015 | 05/17/2017 | 811121 | Richey Collision Center, Inc. |
Abstract: At 5:15 p.m. on May 16, 2017, an employee was preparing to paint a car. The employee hooked up his airline respirator to a nitrogen hose instead of to the compressed air hose, resulting in the employee suffering asphyxiation.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury |
|---|---|---|---|---|---|
| 1 | 1233587.015 | 45 | M | Fatality |
Translate