Accident Summary Nr: 956029 - Commercial divers die of carbon monoxide inhalation

Accident Summary Nr: 956029 -- Report ID: 0932000 -- Event Date: 01/03/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
10252056601/04/199173890Solitude/Echo Espinola

Abstract: Employee #1 and #2, divers using hookah diving gear, were gathering sea urchins in 60 feet of sea water when they inhaled carbon monoxide gas from the surface-supplied air system. The autopsy reports the cause of death for Employee #1 as carbon monoxide poisoning and the cause of death for Employee #2 as carbon monoxide asphyxia. The compliance officer recorded up to 200 ppm of carbon monoxide in the breathing air system. The air intake on the Grainger Speedaire compressor, model #2Z630B, was only 26 inches from the exhaust outlet on a Magnum Kohler 8 gasoline engine. At the time of the incident, the wind conditions were calm and the engine was running. Because the compressor was not fitted with suitable in-line safety and alarm equipment, Grainger, the manufacturer, stated "it should not be used to supply breathing quality air."

Keywords: COMPRESSOR, AIR LINE RESPIRATOR, ASPHYXIATED, ENGINE, POISONING, TOXIC FUMES, GASOLINE, CARBON MONOXIDE, UNGUARDED, COMMERCIAL DIVING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 102520566 Fatality Asphyxia Occupation not reported
2 102520566 Fatality Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close