Accident Summary Nr: 952713 - Employee Is Electrocuted While Welding Equipment

Accident Summary Nr: 952713 -- Report ID: 0355116 -- Event Date: 05/19/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30729094005/20/20042015311615Pilgrim'S Pride Corporation

Abstract: On May 19, 2004, Employee #1, a maintenance employee, was using an argon-gas, single-phase, Miller Tig welder to weld a metal trough back onto a liver machine while standing in water. The welder voltage ranged from 110 volts to 230 volts. As he welded the liver machine, Employee #1 was electrocuted. Coworkers who heard Employee #1 scream and observed him fall backwards, immediately provided assistance by performing CPR. Emergency services were contacted and, upon their arrival, emergency personnel transported Employee #1 to Rockingham Memorial Hospital in Harrisonburg, VA, where he was determined to be dead.

Keywords: PPE, ELECTROCUTED, WELDER, WELDING, ELECTRIC CONDUCTOR, ELECTRIC SHOCK, WORK SURFACE, WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 307290940 Fatality Electric Shock Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close