Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 950089 - Employee's leg amputated in nip point

Accident Summary Nr: 950089 -- Report ID: 0355117 -- Event Date: 07/22/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10575368507/22/199226790Rock-Tenn Company

Abstract: At approximately 10:35 p.m. on July 21, 1992, Employee #1 was on a paper roll take-off table located directly in front of the #2 paper machine rewinder. Employee #1 squatted down, then inserted a utility knife into the seam of two rolls of paper that were approximately 18 3/4 in. in diameter and had begun to overlap as they were being wound by the machine. Employee #1 lost his balance and his left leg was pulled into the in-running nip point created by the winder roll and shaft. Employee #1 sustained crushing injuries to his left leg that resulted in amputation above the knee. He was hospitalized.

Keywords: AMPUTATED, ROTATING SHAFT, WORK RULES, PAPER ROLL, ROLLER--MACH/PART, CRUSHED, NIP POINT, LOST BALANCE, PAPER MACHINE, LEG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105753685 Hospitalized injury Amputation Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.