Accident Summary Nr: 943530 - Employee killed when struck by crane boom

Accident Summary Nr: 943530 -- Report ID: 0453710 -- Event Date: 06/19/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
1847998006/22/199016220Carolina Bridge Co. Inc.

Abstract: Employee #1, along with an operator and a truck driver, was assigned to dismantle a Link Belt 45 ton friction crane. The employees successfully removed two 20 ft sections of boom and the counterweight, attached the tip section of the boom to the base section, and used the crane to load the 20 ft sections and counterweight on a truck. Employee #1 signaled the operator to boom up to head height, walked under the boom, and knocked out the two bottom pins holding the tip and base section together. The boom immediately collapsed at the connection point, striking Employee #1 and trapping him under the boom. The operator used a front end loader to lift the boom and pulled Employee #1 from under the boom. Employee #1 died at the scene of crushing injuries to his chest.

Keywords: CHEST, DISMANTLING, COLLAPSE, CRANE BOOM, WORK RULES, CONSTRUCTION, CRUSHED, STRUCK BY, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18479980 Fatality Other Carpenters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close