Accident Summary Nr: 943456 - Employee killed in fall from forks of lift truck

Accident Summary Nr: 943456 -- Report ID: 0418100 -- Event Date: 07/29/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11010924607/29/199128190Taylor Chemical Company, Inc.

Abstract: Employee #1 was about 27 to 28 ft above a floor in a cage that was on a work platform atop a stand/base on the forks of a lift truck. He was attempting to change a burned-out light bulb. As the cage and stand were being lifted, the mast caught on a beam and then freed itself as it went past. The mast shook violently and shook the cage off the stand. The cage and stand were not attached to each other. Employee #1 was killed when he fell out of the cage and landed on the concrete floor.

Keywords: BEAM, CLEARANCE, UNSECURED, CAUGHT BY, INDUSTRIAL TRUCK, FALL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110109246 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.