Accident Summary Nr: 93781.015 - Worker at die press has finger caught and amputated

Accident Summary Nr: 93781.015 -- Report ID: 0522500 -- Event Date: 03/10/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1216275.01503/09/2017332618Mid West Fabricating Company

Abstract: At 1:00 a.m. on March 10, 2017, Employee #1, employed by a steel fabricator, was working at a die press machine. She was attempting to reposition a misfed work piece. After stopping the press cycle using a foot pedal, she pushed the work piece back into the correct position. The pneumatic material hold clamp activated and extended to its normal position, pinching Employee #1's right index finger between the clamp and the die. Emergency services were called, and Employee #1 was transported to the hospital. She was treated for the partial amputation of her finger.

Keywords: Air Pressure, Amputation, Caught Between, Crushed, Die, Die Cutting Press, Finger, Hold-Down Clamp, Material Handling, Mechanical Power Press

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1216275.015 29 F Non Hospitalized injury Pressing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close