Abstract: At approximately 11:45 a.m. on February 21, 2017, Employee #1 was cutting cardboard for picture frame backing on a SawStop table saw. According to the saw manufacturers documentation, thin kerf blades should not be used for this purpose. The braking system on the saw failed and the blade cracked. Employee #1's finger contacted the blade and was amputated. Employee #1 was not hospitalized.

Keywords: Amputated, Equipment Failure, Finger, Machine Guarding, Struck By, Table Saw

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1212742.015 53 M Non Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.