Accident Summary Nr: 932590 - Employee Killed in Industrial Dryer

Accident Summary Nr: 932590 -- Report ID: 0111400 -- Event Date: 11/21/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10743680011/23/199072180H.L.A. Services, Incorporated

Abstract: Employee #1 was inside an industrial dryer removing a buildup of plastic on the drum. The employee had propped the load door open with a wooden 2 by 4, tripping the door switch. The computerized roller conveyor shuttle received a signal that the load door was open and available to be loaded with two 100-lb batches of wet laundry. The forward-loading movement of the batch of laundry kicked the wood into the dryer and blocked the only means of exit. The dryer's program signaled the drum to revolve, making it impossible for Employee #1 to open the door and exit. He died from being trapped in the dryer for the duration of a 6-minute dry cycle at 230 degrees centigrade.

Keywords: OBSTRUCTED EGRESS, MAINTENANCE, ROTATING PARTS, WORK RULES, DRUM, INTERLOCK, LOCKOUT, HIGH TEMPERATURE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107436800 Fatality Burn/Scald(Heat) Janitors and cleaners

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close