Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 93073.015 - Employee is sprayed with ammonia (NH3) and is hospitalized

Accident Summary Nr: 93073.015 -- Report ID: 0729700 -- Event Date: 02/07/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1209753.01502/13/2017424510Fredonia Cooperative Association

Abstract: At 3:10 p.m. on February 7, 2017, an employee was making preparations to replace the relief valve of a 1,000 gallon ammonia (NH3) nurse tank. The incident investigation reported that the tank was empty of liquid NH3. However, it contained approximately 80 psi of vapor pressure. The employee set up a 30 gallon drum that contained water and affixed it to the nurse tank by way of a hose. He then turned the relief valve of the tank to bleed the vapor pressure into the drum. The vent of the drum was not completely clear, causing the bottom of the drum to burst and become airborne. The drum became separated from the hose and was ejected over the top of the ammonia storage tank, spraying the employee's lower portion of his body with ammonia. The employee sustained chemical burns and showed signs of toxic vapor inhalation, which he was hospitalized and received treatment.

Keywords: Accidental Discharge, Agriculture Machinery/Vehicle, Ammonia, Chemical Burn, Compressed Gas, Ejected, Pressure Vessel, Toxic Fumes

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1209753.015 50 M Hospitalized injury Supervisors, farm workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close