Accident Report Detail
Accident Summary Nr: 92939.015 - Worker is run over by a forklift and his foot requires amput
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1208849.015 | 02/07/2017 | 238220 | Williams Mechanical Llc |
Abstract: At 10:30 a.m. on February 1, 2017, Employee #1 and Coworker #1, both employed by a construction subcontractor, were working at a multiemployer project at a water and sewer treatment plant. Employee #1 was walking alongside a moving Skyjack Telehander rough terrain forklift and trying to balance a steel pipe slung from a fork of the forklift. The schedule 40 pipe was 21 feet long, 16 inches in diameter, and weighed 1,600 pounds. Coworker #1 was operating the forklift and the forklift ran over Employee #1's foot. Emergency services were called, and Employee #1 was transported to the hospital and admitted. His crushed foot required amputation.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Sewer/water treatment plant | Alteration or rehabilitation | 0 | |||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1208849.015 | 63 | M | Hospitalized injury | Welders and cutters |
Translate