Accident Summary Nr: 92445.015 - Employee is scalped when hair is caught in drill press

Accident Summary Nr: 92445.015 -- Report ID: 0524700 -- Event Date: 01/18/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1205094.01501/24/2017332510Cleveland City Forge, Inc.

Abstract: At 3:30 p.m. on January 18, 2017, Employee #1 was using the Cleereman Machine Tool chamfer press to chamfer clevis parts. He reached around the press to tighten the loose part holder when his hair, which was in a ponytail, became caught in the spindle of the drill press, resulting in a scalping of the top and right side of his head, partial right ear and right cheek. There were no immediate witnesses to the accident and the press did not have a guard to protect against the rotating parts.

Keywords: Caught In, Drill Press, Ear, Face, Hair, Head, Machine Guarding, Rotating Parts, Scalped, Spindle, Unguarded

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1205094.015 61 M Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.