Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 92429.015 - Employee sustains fractures and lacerations in unguarded pre

Accident Summary Nr: 92429.015 -- Report ID: 0524700 -- Event Date: 01/17/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1204987.01501/24/2017333924Crown Equipment Corp.

Abstract: At 10:24 a.m. on January 17, 2017, Employee #1, a press brake operator, was operating a Cincinnati Inc. press brake, Serial Number 52916. The press, operated by a foot pedal, was equipped with Link Electric Black Max light curtains, Model LL-MAX-18-AS and Serial Number 8582. There were press setup configurations that required the use of a work support. The employer utilized light curtain blanks to allow the press to be operated with the support when necessary. The blanks were installed by the operator who screws them hand-tight onto a bracket that is on the light curtain, and then used a key, which was always kept in the light curtain box, to program the curtains to run with the blanks. A brake operator on a previous shift utilized a light curtain blank for an order, but the blanks were not removed after completion of the job and removal of the work piece support, or prior to Employee #1s shift. The blank loosened and fell vertically behind the bracket where it went unseen by Employee #1. With the section of the light curtain blanked, and with the work piece support removed, the employee was in the point of operation at the time the press was cycled. The press was not adequately guarded and allowed the employee to reach through to the point of operation where the key was readily available to bypass the guarding. Employee #1 sustained fractures and lacerations to three fingers on his left hand and was hospitalized for his injuries.

Keywords: Finger, Fracture, Laceration, Machine Guarding, Point Of Operation, Press Brake, Unguarded

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1204987.015 51 M Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.