Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 92252.015 - Three employees are electrocuted when crane touches powerlin

Accident Summary Nr: 92252.015 -- Report ID: 0936300 -- Event Date: 01/14/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1203732.01501/17/2017236220Manua'S, Inc.

Abstract: At approximately 11:00 a.m. on January 14, 2017, Employees #1, #2 and #3 were unloading and staging structural metal beams with a boom truck crane. The truck mounted crane was unloading steel beams from an open top container when the boom truck cable touched a high power line causing electrical current to flow down the steel beam into the arms and bodies of Employees #1, #2 and #3, who were on the ground. All three employees were electrocuted.

Keywords: Boom Truck, Crane, Electrocuted, Power Lines
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $50,000 to $250,000 1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1203732.015 21 M Fatality Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Erecting structural steel
Fatality Cause:
2 1203732.015 21 M Fatality Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Erecting structural steel
Fatality Cause:
3 1203732.015 27 M Fatality Laborers, except construction Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Erecting structural steel
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.