Accident Report Detail

Accident Summary Nr: 921585 - Employee struck and killed by concrete pumping hose

Accident Summary Nr: 921585 -- Report ID: 0418200 -- Event Date: 08/30/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11007266709/12/199116290T & B Scottdale Contractors, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
11007267509/11/199117710Pioneer Concrete Pumping Service Inc.

Abstract: At approximately 12:50 p.m. on August 30, 1991, Employee #1, of T & B Scottdale Contractors, Inc., was placing concrete using a manually-controlled concrete delivery hose attached to a concrete pumping truck. The pump truck was owned and operated by Pioneer Concrete Pumping Services, Inc. A Pioneer employee set up the truck, and was controlling the pumping and boom movement. After approximately 20 minutes of pump operation, the truck's right front outrigger broke through its dunnage and sank into the ground. The sudden movement jerked the pump truck boom downward. The employee was struck in the chest and shoulder by the concrete delivery hose, knocked to the ground, and pinned under the hose. He was hospitalized. He died 10 days later on September 9, 1991. The accident occurred because the truck was set up and operated on unstable soil, and the pump truck operator was not properly trained on how to set up the equipment or on how to recognize and avoid unsafe conditions.

Keywords: WORK RULES, EQUIPMENT FAILURE, UNTRAINED, OUTRIGGER, PINNED, CONSTRUCTION, HOSE, STRUCK BY, UNSTABLE SOIL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110072667 Fatality Other Occupation not reported
2 110072675 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.