Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 91351.015 - Employee is asphyxiated while welding in tank

Accident Summary Nr: 91351.015 -- Report ID: 0521100 -- Event Date: 12/14/2016
Inspection NrDate OpenedSICNAICSEstablishment Name
1197139.01512/14/2016332420A&B Process Systems, Inc.

Abstract: At approximately 1:00 a.m. on December 14, 2016, an employee had been welding lift lugs onto the outside of stainless steel tanks. Small metal bladders were placed on the inside surface of the tank where the employee was welding. The metal bladders were supplied with argon and used to purge oxygen from the inside surface of the weld area to eliminate oxidation of the metal during welding outside the tank. It is believed the employee entered the tank to remove the metal bladders and was asphyxiated due to lack of oxygen displaced by the argon gas.

Keywords: Asphyxiated, Confined Space, Oxygen Deficiency, Welder

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1197139.015 26 M Fatality Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.