Accident Summary Nr: 910901 - Employee struck and killed by falling limb

Accident Summary Nr: 910901 -- Report ID: 0454510 -- Event Date: 12/15/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
12466493912/16/199424210Booker Logging Co.

Abstract: Employee #1 was performing his normal job of cutting down trees with a chain saw. When he cut down a large poplar tree it split; one part lodged in a standing tree. Employee #1 signaled to the skidder operator to pull down the lodged portion of the poplar tree. Employee #1 stood out of the area (approximately 35 ft away) as this was being done. After the skidder operator had pulled down the lodged poplar, he dropped it. He then saw Employee #1 lying face down on the ground. It was determined that a limb (4 in. in diameter and 7 ft long) had struck Employee #1 on the left cheek, breaking his neck and fracturing his skull. Employee #1 was killed. The origin of the limb was never found.

Keywords: FRACTURE, TREE FELLING, TREE LIMB, SKULL, NECK, STRUCK BY, FACE, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 124664939 Fatality Fracture Timber cutting and logging occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close