Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 910117 - Employee's fingers injured in closing press

Accident Summary Nr: 910117 -- Report ID: 0454510 -- Event Date: 09/03/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11102684509/24/199135620Torrington Co.

Abstract: Employee #1 was setting up a Bihler part-revolution press that was normally run on automatic and was running parts through for adjustment at the curler station. The welder was not welding where it was supposed to. The press closed, amputating one joint of Employee #1's right index finger and lacerating the thumb. The interlock safety gate was bypassed.

Keywords: AMPUTATED, FINGER, WORK RULES, INTERLOCK, THUMB, LACERATION, PRESS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111026845 Non Hospitalized injury Amputation Misc. metal,plastic,stone&glass-working mach. op's

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.