Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 909747 - Employees overexposed to sulfur dioxide

Accident Summary Nr: 909747 -- Report ID: 0454510 -- Event Date: 10/05/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
12465018510/08/199328430Henkel Corporation

Abstract: At approximately 9:30 p.m. on October 5, 1993, operators were attempting to remove sulfur dioxide from a reactor vessel by passing 50 percent sodium hydroxide (NaOH) through the vessel to form an intermediate with the two chemicals. The operator had failed to determine what vapor or gas was in the vessel before startinig the prcess. Therefore, the operator could not determine the amount of sodium hydroxide that needed to be added to the reactor, and sulfur dioxide vapor was released into the air. Employees #1 through #6 experienced symptoms such as headache, sore throat, and tightness in the chest. They were sent to the hospital and released. Violations of 1910.119 were determined to exist and were cited.

Keywords: CHEST, THROAT, REACTOR, VENTILATION, HEADACHE, WORK RULES, SULFUR DIOXIDE, CHEMICAL VAPOR, OVEREXPOSURE, ACCIDENTAL DISCHARGE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 124650185 Non Hospitalized injury Other Miscellaneous plant and system operators
2 124650185 Non Hospitalized injury Other Miscellaneous plant and system operators
3 124650185 Non Hospitalized injury Other Miscellaneous plant and system operators
4 124650185 Non Hospitalized injury Other Miscellaneous plant and system operators
5 124650185 Non Hospitalized injury Other Miscellaneous plant and system operators
6 124650185 Non Hospitalized injury Other Miscellaneous plant and system operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.