Accident Summary Nr: 904839 - EMPLOYEE'S FINGERS AMPUTATED IN HYDRAULIC PRESS

Accident Summary Nr: 904839 -- Report ID: 0551800 -- Event Date: 01/02/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11496222801/08/199235620Federal-Mogul Corporation

Abstract: AT APPROXIMATELY 10:15 PM ON THURSDAY, JANUARY 2, 1992 (THE FIRST DAY OF PRODUCTION AFTER A CHRISTMAS/NEW YEAR PLANT SHUTDOWN) EMPLOYEE #1 SUFFERED AMPUTATION OF PARTS OF HIS MIDDLE AND RING FINGERS OF HIS RIGHT HAND. AT THE TIME HE WAS PLACING AND REMOVING A CLUTCH BEARING PART INTO THE POINT OF OPERATION OF A MULTIPRESS 18 TON HYDRAULIC PRESS. THE EXISTING PRESENCE SENSING LIGHT CURTAIN SAFETY WAS BYPASSED BY A POORLY ADJUSTED "2LS" LIMIT SWITCH, WHICH IS DESIGNED TO STOP THE DOWNWARD MOTION OF THE RAM AND DIE AT THE POINT WHERE IT ALMOST TOUCHES THE PART. HOWEVER, THE "2LS" LIMIT SWITCH WAS ADJUSTED SO THAT THE RAM STOPPED AT A POINT ALLOWING 1 INCH OF SPACE BETWEEN THE DIE AND SHOE, MOUNTED ON THE BOLSTER PLATE. THE PRESS WAS ACTUATED BY A COVERED FOOT PEDAL. EMPLOYEE #1 WOULD PLACE THE PART INTO THE DIE FIXTURE WITH HIS RIGHT HAND AND REMOVE IT WITH HIS LEFT HAND. HE HAD 6 MONTH EXPERIENCE AT THE JOB AND WAS CROSS TRAINED TO PERFORM A VARIETY OF ASSEMBLING OPERATIONS ON OTHER MACHINES. THE COMPANY HAD A POLICY OF RESTRICTING EMPLOYEE WORK AT ANY ONE JOB FUNCTION TO A PERIOD OF 2 HOURS OR LESS. THE PRESS SET-UP THEY WERE USING WAS NOT EVEN INTENDED FOR THE ASSEMBLY OF THE PART THEY WERE WORKING ON. THE NEED TO HAVE THE "2LS" LIMIT SWITCH OPERATIONAL WAS MEANINGLESS TO THEIR OPERATION. THERE WAS NO POLICY FOR EITHER THE SET-UP PEOPLE OR THE OPERATORS TO PERFORM SAFETY CHECKS ON EACH SHIFT. OPERATOR TRAINING WAS INADEQUATE. WORK ON THIS PARTICULAR CLUTCH BEARING ASSEMBLY OCCURS FOUR DAYS A MONTH. A SERIOUS "NEAR MISS" ACCIDENT HAD OCCURRED ONE WEEK EARLIER WHEN ANOTHER OPERATOR'S GLOVE WAS NIPPED IN THE POINT OF OPERATION, BUT THAT ACCIDENT WAS NEVER REPORTED TO MANAGEMENT.

Keywords: MAINTENANCE, AMPUTATED, FINGER, WORK RULES, HYDRAULIC PRESS, UNTRAINED, PRESS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 114962228 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close