Accident Summary Nr: 903260 - Employee killed when compactor rolls over on steep grade

Accident Summary Nr: 903260 -- Report ID: 0551800 -- Event Date: 10/13/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
12401901910/14/199316110Roberts Asphalt Inc

Abstract: On October 13, 1993, the paving crew was sent to a job site to lay approximately 100 tons of asphalt. They arrived on site at about 1:45 p.m. The Hyster 10 ton compactor was unloaded from the semi lowboy. Employee #1drove the compactor down the lot owner's long access lane to the work site, came to a sharp curve and a very steep hill, and lost control. The compactor skidded approximately 203 feet 10 inches, spun around, and rolled upside down, pinning and crushing Employee #1 under the machine. Employee #1 died from inner cranial bleeding and crushing injuries. The compactor was not equipped with rops or a seat belt, although Hyster has rops available for this piece of equipment. According to Hyster's specifications, this machine should not be used on slopes with a grade greater than 17 percent. The area where Employee #1 lost control of the machine had a slope of 22.5 percent. The job site had not been inspected prior to the accident. Employee #1 was not made aware of the hazard.

Keywords: ROLL-OVER, WORK RULES, ROPS, CONSTRUCTION, DRIVER, STEEP GRADE, CRUSHED, SHARP TURN, LOST CONTROL, ROAD PAVING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 124019019 Fatality Other Paving, surfacing and tamping equipment operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close