Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 899740 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Accident Summary Nr: 899740 -- Report ID: 0355114 -- Event Date: 03/14/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
12368288203/14/199417610North Amercan Roofing Systems Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
12368289003/14/199417610Springfield Rental Crane Co.Inc.

Abstract: The front of a flat bed trailer had been parked beneath a 19.9-kilovolt overhead power line. The power line was 38 feet, 5 inches above the ground and 33 feet, 5 inches above the bed of the trailer. A rented 25-ton P&H truck crane was to be used to unload material from the trailer. Some material had already been unloaded from the rear of the trailer. The truck driver and the crane operator then decided to move the trailer back away from the power line since the pallet of roofing tar and sealant to be unloaded next was under the power line at the front of the trailer. An employee pulled the load line over to the pallet (apparently before the trailer was moved) so that the load could be dragged out from under the power line before it was lifted. As he did this, the load line contacted the power line. The employee received an electric shock, which knocked him off the trailer onto the pavement. In addition to the electric shock, the employee sustained only minor abrasions, contusions, and electrical burns for which he was hospitalized.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, E GI IA, ABRASION, ELECTRIC SHOCK, CONTUSION, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 123682882 Hospitalized injury Electric Shock Roofers
2 123682890 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.