Accident Summary Nr: 896365 - Employee dies of asphyxia in manhole

Accident Summary Nr: 896365 -- Report ID: 0355118 -- Event Date: 06/13/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12661045006/16/199791990City Of Martinsville

Abstract: At approximately 2:08 p.m. on June 13, 1997, Employee #1 and a coworker, water department workers, removed the manhole cover to an 8 ft deep meter pit to confirm the size of the water main. Employee #1 entered the pit by descending a set of ladder rungs along its side. Once his head was below the ground surface, he called out the size of the main to the coworker, who remained outside the pit. The coworker stated that Employee #1 then immediately collapsed and fell to the bottom of the pit. He was removed by the coworker and other employees by means of a rope looped around the his foot. Attempts to revive Employee # 1 were unsuccessful; he died of asphyxia. Meter readings taken at a later time indicated 12.8 percent oxygen in the pit.

Keywords: OXYGEN DEFICIENCY, ASPHYXIATED, CONFINED SPACE, WORK RULES, AIR MONITORING, SCBA, PIT, FALL, MANHOLE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 126610450 Fatality Asphyxia Supervisors, mechanics and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close