Accident Summary Nr: 890384 - Two employees overcome in a confined space

Accident Summary Nr: 890384 -- Report ID: 0352440 -- Event Date: 06/17/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
11958886106/18/199317210Rencor, Inc.

Abstract: Employees #1 and #2 were applying a sealant to the fittings of a water main valve approximately 14 ft below the surface of the road. The valve was located in a cavity that measures 17 ft long by 15 ft wide by 14 ft high that is accessed through a 24 in. diameter manhole. The sealant used was Royston Roskote R-28 rubberized mastic, which is composed of 40 percent asphalt and 30 percent toluene. The site foreman stated that the employees were wearing rubber gloves, goggles, and half-face air purifying respirators. The employees were in the cavity singing and laughing approximately 10 to 15 minutes after entry. The site foreman heard the singing and laughing stop and called the employees. After getting no response, the foreman entered the cavity and found the two employees in a lethargic state. Employees #1 and #2 had not been trained in the hazards associated with the chemical used or in confined space work procedures. The respirator canisters were found to be appropriate for the task and chemical usage combination.

Keywords: CONFINED SPACE, PPE, TOXIC ATMOSPHERE, CONSTRUCTION, TOLUENE, OVEREXPOSURE, UNTRAINED, ASPHALT, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119588861 Hospitalized injury Asphyxia Construction laborers
2 119588861 Hospitalized injury Asphyxia Construction laborers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close