Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 885814 - Five employees treated after BTEX exposure

Accident Summary Nr: 885814 -- Report ID: 1050210 -- Event Date: 10/20/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
10586215503/12/199616290Alaska Petroleum Contractors Inc

Abstract: Employees #1 through #5, of APC, were working at the North Pole Mapco Refinery in Alaska. They were installing a CTX-BIV treatment system that digests soluble BTEX in the plant's water system. The employees were putting in pipe blinds on four tanks that were covered by plastic sheeting. The ventilation pipes released BTEX petroleum hydrocarbon vapors into the breathing air of the workers. All five employees were taken to Fairbanks Hospital. Employees #1 and #2 were held overnight, and Employees #3 through #5 were treated and released.

Keywords: VENTILATION, PPE, WORK RULES, CONSTRUCTION, INHALATION, GAS, CHEMICAL VAPOR, TOXIC FUMES

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105862155 Hospitalized injury Other Carpenters
2 105862155 Hospitalized injury Other Plumbers, pipefitters and steamfitters
3 105862155 Hospitalized injury Other Supervisors; plumbers, pipefitters & steamfitters
4 105862155 Hospitalized injury Other Plumbers, pipefitters and steamfitters
5 105862155 Hospitalized injury Other Plumbers, pipefitters and steamfitters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close