Accident Summary Nr: 884437 - Employees become ill after inhaling carbon monoxide

Accident Summary Nr: 884437 -- Report ID: 0953210 -- Event Date: 09/21/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10468136611/06/198917990Environmental Control Industries

Abstract: At 9:00 a.m. on September 21, 1989, Employees #1 through #7 entered a work area at the Hyatt Hotel's Alpine Jack Restaurant to remove asbestos. An electric power washer was not working so a gasoline-powered machine was brought in as a replacement. The contained work area had 4,000 cfm negative air ventilation, which was not capable of removing carbon monoxide from the machine's exhaust fast enough to prevent carbon monoxide from building up to dangerous levels (estimated in excess of 200 ppm). By 11:00 a.m. the employees began to feel sick and by 12:30 p.m. they left the area, suffering from various symptoms. All seven employees were hospitalized and one required the use of a hyperbaric chamber.

Keywords: VENTILATION, WORK RULES, INHALATION, AIR CONTAMINATION, POISONING, OVEREXPOSURE, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 104681366 Hospitalized injury Asphyxia Helpers, construction trades
2 104681366 Hospitalized injury Asphyxia Helpers, construction trades
3 104681366 Hospitalized injury Asphyxia Helpers, construction trades
4 104681366 Hospitalized injury Asphyxia Helpers, construction trades
5 104681366 Hospitalized injury Asphyxia Helpers, construction trades
6 104681366 Hospitalized injury Asphyxia Helpers, construction trades
7 104681366 Hospitalized injury Asphyxia Helpers, construction trades

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.