Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 880773 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Accident Summary Nr: 880773 -- Report ID: 0830600 -- Event Date: 09/24/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
11612120309/26/199616230Flint Engineering & Construction Co.

Abstract: Some employees were positioning a 305-millimeter-diamter pipe for a pipeline. The employees were using a side boom crane to suspend the pipe. The boom of the crane contacted a 115-kilovolt overhead power line. Three employees received electric shocks and burns. They were hospitalized for their injuries.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, E GI IA, ELECTRIC SHOCK, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 116121203 Hospitalized injury Electric Shock Occupation not reported
2 116121203 Hospitalized injury Electric Shock Occupation not reported
3 116121203 Hospitalized injury Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.