Accident Summary Nr: 87542.015 - Employee is crushed by truck and killed

Accident Summary Nr: 87542.015 -- Report ID: 0418800 -- Event Date: 08/06/2016
Inspection NrDate OpenedSICNAICSEstablishment Name
1167994.01508/08/2016238110Concrete Experts, Inc.

Abstract: At approximately 10:00 a.m. on August 6, 2016, Employee #1 was standing adjacent to a concrete truck waiting for concrete mix. For unknown reasons the concrete truck flipped over onto its passenger side and pinned Employee #1 between the trucks concrete barrel and the soil berm he was standing on. Employee #1 was killed.

Keywords: Construction vehicle, Crushing, Roll-Over
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $1,000,000 to $5,000,000 1 20 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1167994.015 59 M Fatality Concrete and terrazzo finishers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Pouring concrete floor at grade
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.