Accident Summary Nr: 867531 - EMPLOYEE DIES IN CONFINED SPACE ENTRY

Accident Summary Nr: 867531 -- Report ID: 0522300 -- Event Date: 11/16/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10592701611/20/198934430Babcock & Wilcox Co.

Abstract: Employee #1, a welding technician, descended a ladder into a cylindrical component which contained argon gas to check the quality of a pending welding operation near the top of the component. The component was approximately 7 ft diameter and 16.5 ft in depth. This could have been done with a mirror without entering the tank. The bottom openings were covered with removable pads and the only opening was at the top. Employee #1 did not inform management of his intent to enter and an unreported entry had also been made during the previous shift for the same purpose. An additional argon purge had been added during the previous shift and some of the bottom pads removed for ventilation and replaced at the end of the shift. Employee #1 had been informed of the above actions. The time lapse between replacement of the pads and entry of Employee #1 was three hours and twenty minutes. Entry had not been scheduled nor anticipated and the companies confined space procedures were not in place. No tests had been conducted prior to entry. The employee died of asphyxia.

Keywords: ASPHYXIATED, VENTILATION, CONFINED SPACE, VENTING, PURGING, ARGON

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105927016 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close