Accident Summary Nr: 85599.015 - Employee is electrocuted after contacting un-insulated elect

Accident Summary Nr: 85599.015 -- Report ID: 0830400 -- Event Date: 05/20/2016
Inspection NrDate OpenedSICNAICSEstablishment Name
1150598.01505/20/2016325211Benchmark Foam, Inc.

Abstract: At 6:30 a.m. on May 20, 2016, an employee was attempting to cut foam that had expanded out of the mold because they prematurely opened the mold. The foam started to expand and the doors to the machine were not able to be closed. The employee was electrocuted after contacting energized connections on the paddle of the hot wire cutter. The wooden hand paddle of the hot wire cutter had exposed energized connections that the employee contacted. The employee then fell to a lower level outside of the block mold machine.

Keywords: Electrical, Electrocuted, Fall

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1150598.015 29 M Fatality Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.