Accident Summary Nr: 848523 - ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

Accident Summary Nr: 848523 -- Report ID: 0524200 -- Event Date: 10/03/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10615075810/03/198928340Lypho-Med Inc.

Abstract: AN EMPLOYEE WAS CHANGING A FUSE IN THE CONTROL PANEL OF GRUENBERG OVEN. HE REACHED BEHIND THE FUSE TO HOLD A BOLT IN PLACE WHILE HE LOOSENED A NUT. HE WAS ELECTROCUTED WHEN HE CONTACTED THE 480-VOLT CIRCUIT PARTS. THE INTERLOCK FOR THE DOOR EITHER MALFUNCTIONED OR WAS BY-PASSED, LEAVING THE CIRCUIT PARTS INSIDE THE CONTROL PANEL ENERGIZED. THE EMPLOYEE HAD NOT TESTED THE CIRCUIT TO ENSURE THAT IT WAS, IN FACT, DEENERGIZED.

Keywords: FUSE, E GI IV, ELECTRICAL, ELECTROCUTED, ELECTRICAL WORK, INTERLOCK, LOCKOUT, ELECTRICAL CABINET

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 106150758 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.