Accident Report Detail

Accident Summary Nr: 829184 - Two employees killed, two injured during explosion

Accident Summary Nr: 829184 -- Report ID: 0751910 -- Event Date: 01/07/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
11505692101/08/199328510Vogel Paint & Wax Company Inc./Diamond Vogel Paint

Abstract: Employees #1 and #2 were standing on a 2 ft by 35 ft by 8 ft high platform cleaning a resin storage tank. The tank had been soaked with MEK for a month and a half. The employees drained the MEK from the tank and poured 10 gallons of toluene into a job-made pneumatic-powered circulating pump. They then added another 5 gallons of toluene. The ventilation fan on the roof and the flashlight Employees #1 and #2 were using to see inside the tank were not designed for class 1B flammable atmospheres. In addition, no grounding/bonding straps or cables were attached to the tanks and the ventilation system and the hoses were not self-bonding. A galvanized fitting was attached to the end of the hose on the circulating pump to reduce the opening and provide more pressure. An unknown source caused the tank to explode and catch fire. Employees #1 and #2 were killed. Employee #3, who was helping Employees #1 and #2 clean the tank, was hospitalized. Employee #4, who was also working in the area, was treated and released. It could not be determined what actually caused the spark that initiated the explosion and fire.

Keywords: PROTECTIVE GROUNDING, VENTILATION, WORK RULES, FIRE, STORAGE TANK, TANK CLEANING, EXPLOSION, SPARK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 115056921 Fatality Burn(Chemical) Janitors and cleaners
2 115056921 Fatality Burn(Chemical) Janitors and cleaners
3 115056921 Hospitalized injury Burn(Chemical) Janitors and cleaners
4 115056921 Non Hospitalized injury Burn(Chemical) Janitors and cleaners

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.