Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 828285 - Employee killed when caught between rotating machinery

Accident Summary Nr: 828285 -- Report ID: 0751910 -- Event Date: 04/20/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
11505378705/04/199335640Purolator Air Filtration Products Co.

Abstract: Employee #1, a line leader, was working in an air filter plant, making adjustments to air valves and jets while the large rotating carousel was operating. He became caught between the spokes of the carousel and a variable-speed gearbox. His liver was crushed and he died 13 days later while in the hospital. The rotating carousel had not been locked out and was improperly guarded.

Keywords: MAINTENANCE, ROTATING PARTS, WORK RULES, LOCKOUT, CAUGHT BETWEEN, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 115053787 Fatality Other Supervisors, mechanics and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.