Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 828046 - Two employees die in tank explosion

Accident Summary Nr: 828046 -- Report ID: 0751910 -- Event Date: 11/15/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10425372911/27/199028740Nutra-Flo Chemical Co.
Inspection NrDate OpenedSICNAICSEstablishment Name
10426099711/16/199028750Nutra-Flo Chemical Co.

Abstract: Employees #1 and #2 were told to weld a catwalk on a 28 foot by 5 foot diameter tank that contained 1,500 gallons of water. The tank catches fumes of ammonia sulfate and acid. The tank was new and had just been put into use the previous Saturday. Employees #1 and #2 were seen at 9:30 a.m. hoisting equipment to the top of the tank. At 10:00 a.m., two other employees talked with them. Then at 10:05 a.m., an explosion occurred. Employee #1 was thrown approximately 10 feet up and landed on the ground 15 feet from the tank. Employee #2 was thrown approximately 100 feet into a river. His body was not recovered. The top of the tank has not been found. The tank had not been checked for possible explosive fumes. Neither employee was wearing a safety belt or tie off. Welding of the catwalk could have been done at any time during the previous week before startup. A blueprint draftsman stated that the welding was not something that was needed to start up production. According to a sales rep and parts order person, there had never been a policy of testing tanks before welding.

Keywords: FLAMMABLE VAPORS, WORK RULES, WELDING, EXPLOSION, WATER TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 104253729 Fatality Other Welders and cutters
2 104253729 Fatality Other Welders and cutters
3 104260997 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.