Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 825901 - THREE EMPLOYEES APPARENTLY INHALED CHLORINE GAS

Accident Summary Nr: 825901 -- Report ID: 0352450 -- Event Date: 10/10/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
1885887810/10/198673890Arundel Pool Management Corp.

Abstract: AT ABOUT 2:30 PM ON OCTOBER 10, 1986, EMPLOYEE #2 WAS TRANSFERRING MURIATIC ACID BETWEEN PARTIALLY FILLED DRUMS TO MAKE FULL DRUMS AND FREE UP STORAGE SPACE. HE WAS USING A SIPHON PUMP. THE PARTIALLY FILLED DRUMS WERE LEFT OVER FROM THE SUMMER SWIMMING POOL SEASON. WHEN THE CONTENTS OF ONE DRUM CAME IN CONTACT WITH THE CONTENTS OF ANOTHER, A REACTION OCCURED WHICH CAUSED THE EMISSION OF A GREENISH-YELLOW CLOUD TO THE SURROUNDING AREA. AN ANALYSIS OF THE REMAINING LIQUID SHOWED THAT IT WAS 80% CHLORINE AND 20% HYDROCHLORIC ACID. THREE EMPLOYEES WHO WERE NEARBY, INCLUDING EMPLOYEE #2, INHALED THE GAS AND HAD TO BE TAKEN TO A LOCAL HOSPITAL. THEY SUFFERED FROM RESPIRATORY IRRITATION. ALL WERE RELEASED LATER THE SAME DAY.

Keywords: RESPIRATORY, HYDROCHLORIC ACID, WORK RULES, INHALATION, CHLORINE, CHEMICAL REACTION, TOXIC FUMES

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18858878 Hospitalized injury Other Supervisors; handlers,equip-cleaners,laborers nec
2 18858878 Hospitalized injury Other Laborers, except construction
3 18858878 Hospitalized injury Other Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.