Accident Summary Nr: 824862 - EMPLOYEE INJURED WHEN 55 GALLON DRUM EXPLODED

Accident Summary Nr: 824862 -- Report ID: 0352420 -- Event Date: 10/26/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
1882812911/05/198750120Crown Port Services, Inc.

Abstract: ON OCTOBER 26, 1987, EMPLOYEE #1 WAS USING AN EMPTY, UPSIDE DOWN 55 GALLON STEEL DRUM AS A WORK BENCH FOR BURNING BRACKETS FROM A 5/16 INCH STEEL PLATE. HE WAS USING AN OXYGEN-ACETYLENE BURNING TORCH. THE DRUM HAD CONTAINED PROLAC ACRYLIC LACQUER THINNER (FLASH POINT 150 F). THE DRUM HAD NOT BEEN WASHED OUT, ALL FITTINGS WERE IN, AND ITS ONLY LABEL WAS FACING THE GROUND. THE DRUM EXPLODED, BLOWING OFF THE END NEXT TO THE BURNING. THE DRUM AND/OR PLATE AND/OR TORCH STRUCK EMPLOYEE #1 IN THE HEAD AND STOMACH. HIS FACE SHIELD WAS SHATTERED. HE RECEIVED MULTIPLE CONTUSIONS WITH MEMORY LOSS AND POSSIBLE BRAIN DAMAGE. ACCORDING TO HIS EMPLOYER, HE WAS TRAINED IN BURNING BUT NOT IN "RIGHT TO KNOW". THERE WERE NO WRITTEN RULES OR SPECIFIED AREAS FOR BURNING.

Keywords: LACQUER THINNER, HEAD, FLAMMABLE VAPORS, WORK RULES, DRUM, TORCH, EXPLOSION, STRUCK BY, STOMACH, CONTUSION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18828129 Hospitalized injury Bruise/Contus/Abras Specified mechanics and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close