Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 823088 - Employee's fingertip amputated by press brake

Accident Summary Nr: 823088 -- Report ID: 0352440 -- Event Date: 11/09/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
1882593511/24/198735560The Dca Company, Equipment Division

Abstract: Employee #1, a press operator with five years experience, was using a 135 ton Cincinnati press brake, serial #40645, to perform bends to metal parts for bakery equipment. His fingers were at the edge of the die plate as he was pushing on a metal piece that rested in the die. He sustained the amputation of 1 in. of his left index fingertip. Point of operation guards were not provided. The ram measured 10 ft in length and was 42 in. above the floor.

Keywords: DIE, AMPUTATED, PRESS BRAKE, FINGER, WORK RULES, POINT OF OPERATION, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18825935 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.