Accident Summary Nr: 823013 - CONSTRUCTION WORKER INJURED IN FALL FROM ROOF

Accident Summary Nr: 823013 -- Report ID: 0352440 -- Event Date: 10/05/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
1884459710/06/198715220Structural Systems Incorporated

Abstract: A THREE MAN CONSTRUCTION CREW WAS SETTING PREFABRICATED ROOF TRUSSES OVER THE OFFICE AND SUPPORT AREA OF A 128 BED NURSING HOME UNDER CONSTRUCTION. THE FIRST TRUSS WAS BRACED TO STEEL AND THE CONCRETE FLOOR BY A PIECE OF 2 BY 4. THE SUCCEEDING TRUSSES WERE BRACED BY TWO 2 BY 4S ACROSS THE BOTTOM OF THE TRUSSES, TWO 1 BY 3S ACROSS THE TOP OF THE TRUSSES AND ONE 1 BY 3 HORIZONTALLY ACROSS THE VERTICAL END PIECE. DIAGONAL BRACES WERE NOT USED, AND ONLY ONE NAIL WAS USED TO CONNECT THE BRACING TO THE TRUSSES. THE TRUSSES SUDDENLY FELL OVER, STARTING WITH THE FIRST, WHICH KNOCKED ALL THE OTHERS DOWN IN TURN. EMPLOYEE #1 RECEIVED BRUISED RIBS, A BRUISED SPLEEN AND POSSIBLE PINCHED NERVES IN HIS NECK AND SHOULDER WHEN HE FELL ALONG WITH THE TRUSSES. HE WAS HOSPITALIZED. THE ACCIDENT WAS CAUSED BY THE IMPROPER TRUSS BRACING USED BY THE WORK CREW.

Keywords: TRUSS, ROOF, SPLEEN, UNSECURED, CONSTRUCTION, RIB, FALL, NECK, VERTEBRA

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18844597 Hospitalized injury Bruise/Contus/Abras Carpenters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close