Accident Summary Nr: 82012.015 - Worker is Crushed and Killed During Log Cutting

Accident Summary Nr: 82012.015 -- Report ID: 0521700 -- Event Date: 01/04/2016
Inspection NrDate OpenedSICNAICSEstablishment Name
1115599.01501/04/2016321113J&M Wood Products

Abstract: At 1:30 p.m. on January 4, 2016, Employee #1 and three coworkers were working in a saw mill, preparing a log for cutting. The log measured 44 inches in diameter and was 10.3 feet long. After one coworker used a front end loader to move the log with a chain onto the log deck, another coworker climbed up onto the log deck to remove the chain from the forks of the front end loader and signaled for the actuation of the hydraulic arm to push the log into the carriage. While the coworkers cleared the area, Employee #1 became caught between the hydraulic frame and the log, sustaining injuries to his chest and head. Employee #1 was transported to a nearby hospital where he died as a result of his injuries.

Keywords: Caught In, Chest, Crushing, Head, Hydraulic Lift, Logging, Safety Bar, Struck By

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1115599.015 38 M Fatality Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close