Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 817023 - ELECTRIC SHOCK - GROUND FAULT IN ELECTRIC HAMMER OR CORD

Accident Summary Nr: 817023 -- Report ID: 0112000 -- Event Date: 07/10/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
1823241307/11/199015420Charter Oak Restoration, Inc.

Abstract: AN EMPLOYEE WAS OPERATING A BLACK & DECKER 0.75-INCH HAMMER, CHISELING THROUGH A BRICK PARAPET. THE FLEXIBLE EXTENSION CORD SET BEING USED WITH THE ELECTRIC HAMMER WAS A FLAT CORD, NOT DESIGNED FOR HARD USE; AND THE GROUNDING BLADE ON ITS ATTACHMENT PLUG WAS MISSING. THE POWER CORD ON THE TOOL WAS NOT PROVIDED WITH ANY STRAIN RELIEF, AND THE BLACK CONDUCTOR HAD ELECTRICAL TAPE ON IT. THERE WAS AN APPARENT GROUND FAULT IN THE TOOL OR IN ONE OF THE CORDS AND THE EMPLOYEE WAS ELECTROCUTED.

Keywords: E GI V, ELECTRICAL, CORD SET, ELECTROCUTED, ATTACHMENT PLUG, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC CORD, ELEC PORT TOOL--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18232413 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.