Accident Summary Nr: 816991 - EMPLOYEE KILLED AFTER ENTERING A CONFINED SPACE

Accident Summary Nr: 816991 -- Report ID: 0112000 -- Event Date: 11/05/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10077422311/06/198933990Klock

Abstract: Employee #1 entered into an oxygen deficient confined space, a retort furnace. He began to process the advance products load. He entered into the retort furnace to get some of the parts out. He had not purged the retort of hi-g and oxygen gas nor had he turned the argon gas off. The argon remained in the retort furnace and when Employee #1 entered into the retort furnace, he died of asphyxia.

Keywords: FURNACE, OXYGEN DEFICIENCY, ASPHYXIATED, CONFINED SPACE, ARGON

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100774223 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.