Accident Summary Nr: 810382 - ELECTRIC SHOCK - CONTACT WITH WELDING ELECTRODE

Accident Summary Nr: 810382 -- Report ID: 0453710 -- Event Date: 07/27/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
1527458208/09/198817110Beta Construction Inc

Abstract: AN EMPLOYEE WAS WELDING STAINLESS STEEL DUCTWORK. HE WAS WORKING IN A SERVICE CORRIDOR ON THE THIRD FLOOR OF A BUILDING. AT SOME POINT DURING THE COURSE OF THIS JOB, HE REMOVED HIS GLOVES AND CONTINUED TO WELD. HIS LEFT ARM WAS CONTACTING A WATER PIPE WHEN HE APPARENTLY CONTACTED THE WELDING ELECTRODE. THE EMPLOYEE RECEIVED AN ELECTRIC SHOCK, AND HIS HEART STOPPED. THE EMPLOYEE WAS RESUSCITATED AT THE WORKSITE AND THEN TRANSPORTED TO A HOSPITAL, WHERE HE RECOVERED FROM HIS INJURIES.

Keywords: E GI III, ELECTRICAL, CPR, WELDER, WELDING, ELECTRIC SHOCK, WELDING ELECTRODE, METAL PIPE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 15274582 Hospitalized injury Electric Shock Sheetmetal duct installers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.