Accident Summary Nr: 810184 - EMPLOYEE INJURED WHEN FINGERS CAUGHT IN PUNCH PRESS

Accident Summary Nr: 810184 -- Report ID: 0453710 -- Event Date: 07/05/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
1851296208/15/198934690Accuride, Inc.

Abstract: Employee #1 was operating a Bliss Model Number 103 mechanical punch press with a 20-ton capacity. This punch press had a full revolution clutch, foot treadle control, and a Possons "pull-out" device Model BB. Review of the 1988 record of inspection of the "pull-out" device showed it was signed by both Employee #1 and the inspector. The guard adjustment was made to keep fingers 4 in. from point of operation. For some reason Employee #1, with the work piece not properly in place, stuck his hands into the punch press. Employee #1's fingers were caught between the work piece and the upper die. The tip of his left ring finger was amputated, and the right ring finger was cut down to bone between the joint by the fingernail and the tip of finger.

Keywords: DIE BLADES, DIE, AMPUTATED, FINGER, GUARD, LACERATION, POINT OF OPERATION, PUNCH PRESS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18512962 Non Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close