Accident Report Detail
Accident Summary Nr: 80711.015 - Worker is Crushed and Killed by Split Coil
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1103044.015 | 10/30/2015 | 3312 | 331221 | 104593 - Century Tube Llc |
Abstract: On October 28, 2015, a worker was operating an overhead crane with a "C" hook to load split coils onto a transport rack. One of the coils fell towards him and pinned him against the split coils on the transport rack. The worker died as a result of his injuries sustained.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1103044.015 | 55 | M | Fatality | Occupation not reported |
Translate